Products
Input ±100 - ±2000A, Output ±4V, Power Supply ±15V, Aperture 41x12mm.
The TKC-FR series current sensor is an open loop device provides accurate electronic measurement of DC, AC or pulsed currents. This series current sensor has rated current input between 100A and 2000A, meansure range upto 3000A, with wire, no potentiometer. It has 1% accuracy, very small size, very reliable. Available for appearance customization.
Technology :
Open loop Hall effectMax. Nominal Value :
±2000AMax. Measuring Range :
±3000AOutput Signal :
±4VSupply Voltage :
±15V ±5%Accuracy :
1%Op. Temperature :
-40 °C / 105 °CMounting :
Aperture 41x12mmWeight :
225gMOQ :
100
Electrical data(Ta=25℃±5℃,RL=2KΩ,CL=10000PF) |
Type |
TKC 100FR |
TKC 300FR |
TKC 500FR |
TKC 800FR |
TKC 1000FR |
TKC 1500FR |
TKC 2000FR |
Unit |
Ratedinput(Ipn) |
±100 |
±300 |
±500 |
±800 |
±1000 |
±1500 |
±2000 |
A |
Measurerange(Ip) |
±300 |
±900 |
±1500 |
±2400 |
±3000 |
±3000 |
±3000 |
A |
Rated output |
@Ip=±Ipn ±4±1% |
V |
||||||
Supply voltage |
±15±5% |
V |
||||||
PowerConsumption |
+18,-10 |
mA |
||||||
Offset voltage |
@Ip=0 ≤15 |
mV |
||||||
Magnetic offset |
@Ip=±Ipn ≤±30 |
mV |
||||||
Offset drift |
@ -40~+85℃ ≤±0.5(Typ),≤±0.75(Max) |
mV/℃ |
||||||
output drift |
@ -40~+85℃ ≤±0.5(Typ),≤±0.75(Max) |
mV/℃ |
||||||
Linearity |
@Ip=0-±Ipn ≤1 |
%FS |
||||||
Response time |
@50A/μS, 10%-90% ≤5 |
μS |
||||||
Bandwidth |
@-3dB DC±25 |
KHz |
||||||
Galvanic isolation |
@ 50HZ,AC,1min 5.0 |
KV |
||||||
Creepage distance |
>8.5 |
mm |
||||||
Clearance distance |
>8.5 |
mm |
||||||
Comparative tracking index(Group 111a |
>275 |
V |
*Product updates, iterations, and parameter changes will not be notified separately
Applications |
Variable speed drives
Welding machine
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Electrochemical
Mechanical dimension(for reference only) |
Remarks:
1. All dimensions are in mm.
2. General tolerance ±1mm.
Directions for use |
1. When the current will be measured goes through a sensor, the voltage will be measured at the output end.
(Note: The false wiring may result in the damage of the sensor)
2. Customs can adjust output amplitude of the sensor by needs.
3. Custom design in the different rated input current and the output voltage are available.
Add: NO.80 Feitian Avenue, Lukou Street, Jiangning District, Nanjing City
Copyright @2023 Nanjing Token Electronics Science&Technology Co., Ltd. All Rights Reserved. Sitemap | Blog | Xml | Privacy Policy Network Supported