Hall Effect Current Sensor

Products

Home Open Loop Current Transducer

TKC-EKBDA12 Open Loop Dismountable Hall Effect Current Tranducer

2000A Current Transducer
Split-Core Current Transducer
Open Loop Current Transducer
Dismountable Current Transducer

TKC-EKBDA12 Open Loop Dismountable Hall Effect Current Tranducer

The TKC-EKBD12 series current transducer is an open loop device with a galvanic isolation between primary and secondary circuit, it provides accurate electronic measurement of AC or pulsed currents. This dismountable series current transducer has rated current input between 200A and 2000A, meansure range upto 3000A. It has 1% accuracy, very reliable. Available for appearance customization.

  • Technology :

    Open loop Hall effect
  • Max. Nominal Value :

    2000A
  • Max. Measuring Range :

    3000A
  • Output Signal :

    4~20mA
  • Supply Voltage :

    12V ±5%
  • Accuracy :

    1%
  • Op. Temperature :

    -40 °C / 85 °C
  • Mounting :

    Aperture Φ40.5mm
  • Weight :

    283g
  • MOQ :

    60
  • Description

 Electrical data (Ta=25℃±5℃,RL=2KΩ,CL=10000PF)

 

 

Type
Parameter

TKC200

EKBDA12

TKC500

EKBDA12

TKC800

EKBDA12

TKC1000

EKBDA12

TKC1500

EKBDA12

TKC2000

EKBDA12

Unit

Rated current(Ipn AC)

200

500

800

1000

1500

2000

A

Measuring range(Ip AC)

0-400

0-1000

0-1600

0-2000

0-3000

0-3000

A

Rated output (Io DC)

@Ip=0-Ipn AC           4~20±1.0%

mA

Supply voltage

12 ±5%

V

Power Consumption

+35+Io

mA

Measure resister (RM)

100-350

Ω

Zero current

@Ip=0                4±0.1

mA

Offset drift

@ -40~+85℃          ≤±0.005

mA/℃

output drift

@ -40~+85℃          ≤±0.005

mA/℃

Linearity

@Ip=Ipn    AC         ≤1

%FS

Response time

≤200

mS

Bandwidth

@-3dB                  40~10000

Hz

Galvanic isolation

@50HZ, AC,1min         5

KV

 

 Applications

 

Variable speed drives

Welding machine

Battery supplied applications

Uninterruptible Power Supplies (UPS)

Electrochemical

 

 Mechanical dimension (for reference only)

current transducer drawing 

 

Remarks:

1. All dimensions are in mm.

2. General tolerance ±1mm.

 

 Directions for use

 

1.When the current will be measured goes through a transmitter, the current will be measured at the output end.

(Note: The false wiring may result in the damage of the transmitter)

2.Customs can adjust output amplitude of the transmitter by needs.

3.Custom design in the different rated input current and the output current are available.

 

 Further Note

 

L/T: Large quantity in 14 days

customized: Support OEM/ODM, Laser marking, Packing

Warranty: 2.5 years

After-sale service: within 24 hours 

 

 Packing and Shipment

 

 

 

Packing and Shipment

leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

RELATED PRODUCTS

Open Loop Current Transducer
TKC-BSD Open Loop Hall Effect Current Transducer
The TKC-BSD series current transducer is an open loop device with a galvanic isolation between primary and secondary circuit, it provides accurate electronic measurement of AC or pulsed currents. This series current transducer has rated current input between 50A and 600A, meansure range upto 650A. It has 1% accuracy, very small size, very reliable. Available for appearance customization.
Current Transducer Factory
TKC-BRD Open Loop Hall Effect Current Transducer
The TKC-BRD series current transducer is an open loop device with a galvanic isolation between primary and secondary circuit, it provides accurate electronic measurement of AC or pulsed currents. This series current transducer has rated current input between 50A and 600A, meansure range upto 650A, provide wire. It has 1% accuracy, very small size, very reliable. Available for appearance customization.
Dismountable Current Transducer
TKC-EKAD Open Loop Dismountable Hall Effect Current Tranducer
The TKC-EKAD series current transducer is an open loop device with a galvanic isolation between primary and secondary circuit, it provides accurate electronic measurement of AC or pulsed currents. This dismountable series current transducer has rated current input between 30A and 500A, meansure range upto 1000A. It has 1% accuracy, very reliable. Available for appearance customization.
Dismountable Current Transducer
TKC-EKADA12 Open Loop Dismountable Hall Effect Current Tranducer
The TKC-EKAD12 series current transducer is an open loop device with a galvanic isolation between primary and secondary circuit, it provides accurate electronic measurement of AC or pulsed currents. This dismountable series current transducer has rated current input between 20A and 500A, meansure range upto 1000A. It has 1% accuracy, very reliable. Available for appearance customization.
Dismountable Current Transducer
TKC-EKADA24 Open Loop Dismountable Hall Effect Current Tranducer
The TKC-EKAD24 series current transducer is an open loop device with a galvanic isolation between primary and secondary circuit, it provides accurate electronic measurement of AC or pulsed currents. This dismountable series current transducer has rated current input between 20A and 500A, meansure range upto 1000A. It has 1% accuracy, very reliable. Available for appearance customization.
2000A Current Transducer
TKC-EKBDA12 Open Loop Dismountable Hall Effect Current Tranducer
The TKC-EKBD12 series current transducer is an open loop device with a galvanic isolation between primary and secondary circuit, it provides accurate electronic measurement of AC or pulsed currents. This dismountable series current transducer has rated current input between 200A and 2000A, meansure range upto 3000A. It has 1% accuracy, very reliable. Available for appearance customization.
2000A Current Transducer
TKC-EKBDA24 Open Loop Dismountable Hall Effect Current Tranducer
The TKC-EKBD24 series current transducer is an open loop device with a galvanic isolation between primary and secondary circuit, it provides accurate electronic measurement of AC or pulsed currents. This dismountable series current transducer has rated current input between 200A and 2000A, meansure range upto 3000A. It has 1% accuracy, very reliable. Available for appearance customization.
Current Sensor
TKC-KD Open Loop Dismountable Hall Effect Current Transmitter
The TKC-KD series current transducer is an open loop device with a galvanic isolation between primary and secondary circuit, it provides accurate electronic measurement of AC or pulsed currents. This dismountable series current transducer has rated current input between 100A and 2000A, meansure range upto 2500A. It has 5% accuracy, very reliable. Available for appearance customization.
Current Sensor
TKC-KDA Dismountable Hall Effect Current Transmitter
The TKC-KDA series current transducer is an open loop device with a galvanic isolation between primary and secondary circuit, it provides accurate electronic measurement of AC or pulsed currents. This dismountable series current transducer has rated current input between 100A and 2000A, meansure range upto 3000A. It has 5% accuracy, very reliable. Available for appearance customization.
Closed Loop Current Sensor
TKC-KDQT Dismountable Hall Effect Current Transmitter
The TKC-KDQT series current transducer is an open loop device with a galvanic isolation between primary and secondary circuit, it provides accurate electronic measurement of AC or pulsed currents. This dismountable series current transducer has rated current input between 100A and 2000A, meansure range upto 3000A. It has 5% accuracy, very reliable. Available for appearance customization.
Current Sensor Factory
TC-LTAD Current Transmitter
The TKC-LTAD series current transducer is an open loop device with a galvanic isolation between primary and secondary circuit, it provides accurate electronic measurement of AC or pulsed currents. This dismountable series current transducer has rated current input between 0.3A and 100A, meansure range upto 200A. It has 5% accuracy, very reliable. Available for appearance customization.
oppo Loop Current Sensor
TC-LTAD2420 Current Transmitter
The TKC-LTAD2420 series current transducer is an open loop device with a galvanic isolation between primary and secondary circuit, it provides accurate electronic measurement of AC or pulsed currents. This dismountable series current transducer has rated current input between 0.3A and 100A, meansure range upto 200A. It has 5% accuracy, very reliable. Available for appearance customization.
More products uploading
More products uploading
More products uploading
Contact Us

Add: NO.80 Feitian Avenue, Lukou Street, Jiangning District, Nanjing City

Subscribe

Please read on, stay posted, subscribe, and we welcome you to tell us what you think.

submit
b f i t y

Copyright @2023 Nanjing Token Electronics Science&Technology Co., Ltd. All Rights Reserved. Sitemap | Blog | Xml | Privacy Policy Network Supported

leave a message

leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
submit

home

products

Contact Us