Products
TBV-LV series voltage sensor is a closed loop device galvanic isolation between primary and secondary circuit, it can measure DC, AC and pulse voltage. The output from the voltage sensor can be expressed as a voltage by passing it through a resister. Input voltage can be expressed as a current by passing it through a input resister. This series voltage sensor has rated voltage input between±100and ±5000v It has 0.5% accuracy, very reliable. Available for appearance customization.
Technology :
Closed loop Hall effectMax. Nominal Value :
±5000VMax. Measuring Range :
±7000VOutput Signal :
±50mASupply Voltage :
±50±0.5%Accuracy :
0.5%Op. Temperature :
-40 °C / 105 °CMounting :
PCBWeight :
850gMOQ :
100
Electrical data(Ta=25℃±5℃) |
Type |
TBV 100LV |
TBV 300LV |
TBV 500LV |
TBV 1000LV |
TBV 2000LV |
TBV 3000LV |
TBV 4000LV |
TBV 5000LV |
Unit |
Rated input (Vpn) |
±100 |
±300 |
±500 |
±1000 |
±2000 |
±3000 |
±4000 |
±5000 |
V |
Measurerange(Vp) |
±200 |
±600 |
±1000 |
±2000 |
±4000 |
±6000 |
±6000 |
±7500 |
V |
Totalinputconsumption |
1.000 |
1.500 |
3.125 |
2.500 |
5.000 |
5.625 |
10 |
8 |
W |
Rated input (Ip) |
10.000 |
5.000 |
6.250 |
2.500 |
2.500 |
1.875 |
2.500 |
1.600 |
mA |
Turns ratio(Np/Ns) |
5000:1000 |
10000:1000 |
8000:1000 |
20000:1000 |
20000:1000 |
26666:1000 |
20000:1000 |
30000:960 |
T |
Secondary coilresister |
@ +85℃ 55 |
Ω |
|||||||
Rated output (Isn) |
@Vp=±Vpn ±50±0.5% |
mA |
|||||||
Resister measured |
@ ±15V VPN 50(min), 200(max) |
Ω |
|||||||
@ ±15V 2XVPN 0(min), 100(max) |
Ω |
||||||||
@ ±24V VPN 100(min), 330(max) |
Ω |
||||||||
@ ±24V 2XVPN 100(min), 200(max) |
Ω |
||||||||
Supply voltage |
±15 - ±24 |
V |
|||||||
Consumption current |
20+IpX(Np/Ns) |
mA |
|||||||
Offset current |
@ Vp=0 ≤±0.2 |
mA |
|||||||
Offset drift |
@ -40~+85℃ ≤±1.5; @ -50~-40℃ ≤±1.0; |
mA |
|||||||
Linearity |
@ Vp =0-±Vpn ≤0.1 |
%FS |
|||||||
Response time |
≤200 |
uS |
|||||||
Galvanic isolation |
@ 50HZ,AC,1min Between primary and secondary + shield 10.0 |
KV |
|||||||
@ 50HZ,AC,1min Between secondary and shield 2.0 |
KV |
*Product updates, iterations, and parameter changes will not be notified separately
Applications |
Variable speed drives
Welding machine
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Electrochemical
Mechanical dimension(for reference only) |
Remarks:
1. All dimensions are in mm.
2. General tolerance ±1mm
Directions for use |
1. Is is positive when the Ip is applied to the terminal +HT. Temperature of the primary conductor should not exceed 100℃.
2. When the voltage will be measured goes through a sensor, the current will be measured at the output end.
(Note: The false wiring may result in the damage of the sensor)
3. Custom design in the different rated input voltage and the output current available.
Further Note |
L/T: Large quantity in 14 days
customized: Support OEM/ODM, Laser marking, Packing
Warranty: 2.5 years
After-sale service: within 24 hours
Packing and Shipment |
Add: NO.80 Feitian Avenue, Lukou Street, Jiangning District, Nanjing City
Copyright @2023 Nanjing Token Electronics Science&Technology Co., Ltd. All Rights Reserved. Sitemap | Blog | Xml | Privacy Policy Network Supported