Products
TBC-TBH High Accuracy Closed Loop Hall Effect Current Sensor
TBC-TBH Series current sensor is a closed loop device uses for precision measurement of DC, AC and pulse current. It can really measure resolution 1000:1. The size of primary doesn’t affect test precision, no matter the location of primary in the hole of current sensor. This series current sensor has rated current input between 300A and 500A, meansure range upto 1500A. It has 0.2% accuracy, very reliable. Available for appearance customization.
Technology :
Closed loop Hall effectMax. Nominal Value :
±500AMax. Measuring Range :
±1500AOutput Signal :
100mASupply Voltage :
±15~±24VAccuracy :
0.2%Op. Temperature :
-40 °C / 85 °CMounting :
Aperture Φ 35mmWeight :
329gMOQ :
40
Electrical data (Ta=25℃±5℃) |
Type |
TBC300TBH |
TBC400TBH |
TBC500TBH |
Unit |
Rated input (Ipn) |
±300 |
±400 |
±500 |
A |
Measure range(Ip) |
±900(±24V,33Ω) |
±1200(±24V,20Ω) |
±1500(±24V,1.0Ω) |
A |
Measure resister with ±15V |
@±300Amax 100(max) |
@±400Amax 75(max) |
@±500Amax 50(max) |
Ω |
@±600Amax 27(max) |
@±800Amax 15(max) |
@±1000Amax 10(max) |
Ω |
|
Measure resister with ±18V |
@±300Amax 150(max) |
@±400Amax 110(max) |
@±500Amax 100(max) |
Ω |
@±600Amax 43(max) |
@±800Amax 25(max) |
@±1000Amax 7.5(max) |
Ω |
|
Turns ratio(Np/Ns) |
1:3000 |
1:4000 |
1:5000 |
|
Secondary coil resister |
40 |
55 |
75 |
Ω |
Rated output (Isn) |
@Ip=±Ipn ±100±0.2%FS |
mA |
||
Supply voltage |
±15~±24 |
V |
||
Power consumption |
20+IpX(Np/Ns) |
mA |
||
Zero offset current |
@Ip=0 ≤±0.2 |
mA |
||
Offset current drift |
@ -40℃~85℃ ≤±0.5(Typ), ≤±0.75(Max), |
mA |
||
Response time |
@100A/μS,10%-90% <1 |
μs |
||
Linearity |
@Ip=0-±Ipn ≤0.1 |
%FS |
||
Galvanic isolation |
@ 50HZ,AC,1min 6 |
KV |
||
di/dt accurately followed |
>100 |
A/μs |
||
Bandwidth |
@-3dB DC±100 |
KHz |
Applications |
Variable speed drives
Welding machine
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Electrochemical
Mechanical dimension (for reference only) |
Remarks:
1. All dimensions are in mm.
2. General tolerance ±1mm
Directions for use |
1. Is will be in a forward direction when the Ip flows according to the direction of the arrowhead.
2. The primary conductor should be≤120℃.
3. The dynamic performance (di/dt and the response time) is the best when the primary hole is fully filled with the bus bar.
Further Note |
L/T: Large quantity in 14 days
customized: Support OEM/ODM, Laser marking, Packing
Warranty: 2.5 years
After-sale service: within 24 hours
Packing and Shipment |
Add: NO.80 Feitian Avenue, Lukou Street, Jiangning District, Nanjing City