Products
TBC-SYH565 series current sensor provides accurate electronic measurement of DC, AC or pulsed currents.It has strong anti-jamming ability.This series current sensor has rated current input between ±3and ±50A, meansure range upto ±150A. It has 0.5% accuracy, very small size, very reliable. Available for appearance customization.
Technology :
Closed loop Hall effectMax. Nominal Value :
±50AMax. Measuring Range :
±150AOutput Signal :
±0.625VSupply Voltage :
+5±5%Accuracy :
0.5%Op. Temperature :
-40 °C / ±105°CMounting :
PCBWeight :
12gMOQ :
100
Electrical data(Ta=25℃±5℃,RL=2KΩ,CL=10000PF) |
Type Parameter |
TBC03 SYH565 |
TBC05 SYH565 |
TBC10 SYH565 |
TBC15 SYH565 |
TBC20 SYH565 |
TBC25 SYH565 |
TBC30 SYH565 |
TBC50 SYH565 |
Unit |
Rated input (Ipn) |
±3 |
±5 |
±10 |
±15 |
±20 |
±25 |
±30 |
±50 |
A |
Measuringrange(Ip) |
±9 |
±15 |
±30 |
±45 |
±60 |
±75 |
±90 |
±150 |
A |
Size of input pins |
ø 0.6 |
ø 0.8 |
ø 1.0 |
ø 1.0 |
ø 1.4 |
ø 1.4 |
ø 1.6 |
□1.6 ×1.5×2 |
mm |
Turns ratio(Np/Ns) |
5:1440 |
3:1440 |
2:1280 |
2:1440 |
1:1280 |
1:1200 |
1:960 |
1:960 |
T |
Inside resistance |
15 ±0.1% |
15 ±0.1% |
10 ±0.1% |
7.5 ±0.1% |
10 ±0.1% |
7.5 ±0.1% |
5 ±0.1% |
3 ±0.1% |
Ω |
Rated output |
@ Ip=±Ipn ±0.625±0.5% |
V |
|||||||
Supply voltage |
+5±5% |
V |
|||||||
Powerconsumption |
15+IpX(Np/Ns) |
mA |
|||||||
Zero voltage |
2.5±0.4% |
mV |
|||||||
Offset drift |
@ -40~+105℃ ≤±0.1 |
mV/℃ |
|||||||
Output drift |
@ -40~+105℃ ≤±0.1 |
mV/℃ |
|||||||
Linearity |
@ Ip=0-±Ipn ≤0.1 |
%FS |
|||||||
Response time |
@ Ip=Ipn, 50 A/µS ,10%-90% <0.5 |
μS |
|||||||
Bandwidth |
@-3dB DC±100 |
KHz |
|||||||
Galvanic isolation |
@ 50HZ,AC,1min 3.5 |
KV |
*Product updates, iterations, and parameter changes will not be notified separately
Applications |
Switched Mode Power Supplies (SMPS)
AC variable speed drives
Uninterruptible Power Supplies (UPS)
Electrical appliances
Battery supplied applications
DC motor drives
Mechanical dimension(for reference only) |
Remarks:
1. All dimensions are in mm.
2. Secondary pin size and tolerance: width:0.5±0.1mm;thickness:0.25±0.05mm
3. General tolerance ±1mm
Directions for use |
1.When the current will be measured goes through the primary pin of a sensor, the voltage will be measured at
the output end. (Note: The false wiring may result in the damage of the sensor).
2. Custom design in the different rated input current and the output voltage are available.
Further Note |
L/T: Large quantity in 14 days
customized: Support OEM/ODM, Laser marking, Packing
Warranty: 2.5 years
After-sale service: within 24 hours
Packing and Shipment |
Add: NO.80 Feitian Avenue, Lukou Street, Jiangning District, Nanjing City
Copyright @2023 Nanjing Token Electronics Science&Technology Co., Ltd. All Rights Reserved. Sitemap | Blog | Xml | Privacy Policy Network Supported