Products
TBC-ECS5 series current sensor provides accurate electronic measurement of DC, AC or pulsed currents. This series current sensor has rated current input between ±10and ±100 meansure range upto ±200A. It has 0.5% accuracy, very small size,very reliable. Available for appearance customization.
Technology :
Closed loop Hall effectMax. Nominal Value :
±100AMax. Measuring Range :
±200AOutput Signal :
±1.0VSupply Voltage :
+5±2.0%Accuracy :
0.5%Op. Temperature :
-40 °C / ±105°CMounting :
Aperture8.5mmWeight :
15gMOQ :
100
Electrical data(Ta=25℃±5℃) |
Type Parameter |
TBC10ES5 |
TBC25ECS5 |
TBC50ECS5 |
TBC75ECS5 |
TBC100ECS5 |
Unit |
Rated input (Ipn) |
±10 |
±25 |
±50 |
±75 |
±100 |
A |
Measure range(Ip) |
±20 |
±50 |
±100 |
±150 |
±200 |
A |
Turns ratio(Np/Ns) |
1:1000±0.1% |
1:1000±0.1% |
1:1000±0.1% |
1:1500±0.1% |
1:2000±0.1% |
T |
Inside measuring resistance |
25±0.1% |
10±0.1% |
5±0.1% |
5±0.1% |
5±0.1% |
Ω |
Rated output |
@Ip=±Ipn ±1.0±0.5% |
V |
||||
Supply voltage |
+5±2.0% |
V |
||||
Power consumption |
20+IpX(Np/Ns) |
mA |
||||
Reference voltage |
+2.5±0.4% |
V |
||||
Zero voltage |
@Ip=0 +2.5±0.4% |
V |
||||
Offset voltage drift |
@ -40℃~105℃ ≤±0.1 |
mV/℃ |
||||
output drift |
@ -40℃~105℃ ≤±0.1 |
mV/℃ |
||||
Linearity |
@Ip=0-±Ipn ≤0.1 |
%FS |
||||
Bandwidth |
@-3dB DC±100 |
KHz |
||||
Response time |
@100A/μS,10%-90% ≤0.5 |
µs |
||||
Galvanic isolation |
@ 50HZ,AC,1min 3 |
KV |
*Product updates, iterations, and parameter changes will not be notified separately
Applications |
Variable speed drives
Welding machine
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Electrochemical
Mechanical dimension(for reference only) |
Remarks:
1. All dimensions are in mm.
2. General tolerance ±1mm
Directions for use |
1. Is will be in a forward direction when the Ip flows according to the direction of the arrowhead.
2. The primary conductor should be≤120℃.
3. The dynamic performance (di/dt and the response time) is the best when the primary hole is fully filled with the bus bar.
4. The primary turns should be at the top of the sensor for the best magnetic coupling.
5. When the current will be measured goes through a sensor, the voltage will be measured at the output end.
(Note: The false wiring may result in the damage of the sensor)
6. Custom design in the different rated input current and the output current available.
urther Note |
L/T: Large quantity in 14 days
customized: Support OEM/ODM, Laser marking, Packing
Warranty: 2.5 years
After-sale service: within 24 hours
Packing and Shipment |
Add: NO.80 Feitian Avenue, Lukou Street, Jiangning District, Nanjing City