Products
TBC-ECH series current sensor provides accurate electronic measurement of DC, AC or pulsed currents. This series current sensor has rated current input between ±25and ±100 meansure range upto ±300A. It has 0.5% accuracy, very reliable. Available for appearance customization.
Technology :
Closed loop Hall effectMax. Nominal Value :
±100AMax. Measuring Range :
±300AOutput Signal :
±25A,±50ASupply Voltage :
±12~±18VAccuracy :
0.5%Op. Temperature :
-40 °C / ±105°CMounting :
Aperture 8.5mmWeight :
15gMOQ :
100
Electrical data(Ta=25℃±5℃) |
Type Parameter |
TBC25ECH |
TBC50ECH |
TBC75ECH |
TBC100ECH |
Unit |
Rated input (Ipn) |
±25 |
±50 |
±75 |
±100 |
A |
Measure range(Ip) |
±75(±18V,180Ω) |
±150(±18V,75Ω) |
±225(±18V,60Ω) |
±300(±18V,45Ω) |
A |
Turns ratio(Np/Ns) |
1:1000 |
1:1000 |
1:1500 |
1:2000 |
|
Coil resister |
35 |
30 |
40 |
55 |
Ω |
Measure resister with ±12V |
@±50Amax 395(max) |
@±50Amax 180(max) |
@±75Amax 170(max) |
@±100Amax 150(max) |
Ω |
@±75Amax 248(max) |
@±75Amax 110(max) |
@±150Amax 60(max) |
@±300Amax 10(max) |
Ω |
|
Measure resister with ±15V |
@±50Amax 515(max) |
@±50Amax 240(max) |
@±50Amax 230(max) |
@±100Amax 210(max) |
Ω |
@±75Amax 325(max) |
@±75Amax 145(max) |
@±150Amax 40(max) |
@±300Amax 25(max) |
Ω |
|
Rated output (Isn) |
±25±0.5%FS |
±50±0.5%FS |
±50±0.5%FS |
±50±0.5%FS |
mA |
Supply voltage |
±12~±18 |
V |
|||
Power consumption |
20+IpX(Np/Ns) |
mA |
|||
Offset current |
@Ip=0 ≤±0.2 |
mA |
|||
Offset drift |
@ -40℃~85℃ ≤±0.5(Typ), ≤±0.75(Max), |
mA |
|||
Linearity |
@Ip=0-±Ipn ≤0.1 |
%FS |
|||
Bandwidth |
@-3dB DC±100 |
KHz |
|||
Response time |
@100A/μS,10%-90% <1.0 |
μs |
|||
Galvanic isolation |
@ 50HZ,AC,1min 3 |
KV |
*Product updates, iterations, and parameter changes will not be notified separately
Applications |
Variable speed drives
Welding machine
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Electrochemical
Mechanical dimension(for reference only) |
Remarks:
1. All dimensions are in mm.
2. General tolerance ±1.0mm
Directions for use |
1. Is will be in a forward direction when the Ip flows according to the direction of the arrowhead.
2. The primary conductor should be≤120℃.
3. The dynamic performance (di/dt and the response time)is the best when the primary hole is fully filled with the bus bar.
4. The primary turns should be at the top of the sensor for the best magnetic coupling.
5. When the current will be measured goes through a sensor, the voltage will be measured at the output end.
(Note: The false wiring may result in the damage of the sensor)
6. Custom design in the different rated input current and the output current are available.
Further Note |
L/T: Large quantity in 14 days
customized: Support OEM/ODM, Laser marking, Packing
Warranty: 2.5 years
After-sale service: within 24 hours
Packing and Shipment |
Add: NO.80 Feitian Avenue, Lukou Street, Jiangning District, Nanjing City